*OSEMnoiseworstproto_disp.dat The worst measured noise level of prototype OSEMs in [um/rtHz]. The reference xml file can be found in TAMA standalone (133.40.117.66): /users/user_20m/sekiguchi/payload_k1visproto/140919_LOCKED_OSEM_FFT.xml *LVDTnoiseworstproto_disp.dat The worst measured noise level of prototype LVDTs in [um/rtHz]. We assume calibration factor of 1400 [ct/mm]. The reference xml file can be found in TAMA standalone (133.40.117.66): /users/user_20m/sekiguchi/LVDT/130405_LVDT_noise_act.xml *GEOnoiseproto_vel.dat The noise level of geophone preamp in [um/sec/rtHz], but the decrease of geophone response at low freqencies is not compensated. *KamiokaSeismicHighNoise.dat Kamioka seismic spectrum in [m/rtHz]. The low frequency part (<2 Hz) is measured by CMG-3T and 90% pertile of 1.5 years measurement is taken. The high frequency part is interpolation with a function proportional to f^-2. (29/06/2015 updated: < 30 mHz the magnitude is set constant) *LVDTnoiseADC_disp.dat The noise level of LVDTs in [um/rtHz], assuming that the noise is limited by the ADC noise. We assume calibration factor of 1400 [ct/mm].